Continuous Standby Power
Rating Models:
5211 20 kW, 5213 25 kW, 5220 40 kW, 5222 40 kW all
Liquid Cooled Quietsource Generators
![]()

Does
not come with transfer switch
Click
here for recommended Quietsource transfer switches
|
|
||
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
TEST CRITERIA: >PROTOTYPE TESTED >SYSTEM TORSIONAL TESTED >ELECTRO-MAGNETIC INTERFERENCE >NEMA MG1-22 EVALUATION >MOTOR STARTING ABILITY
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.
SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM.
GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
|
GENERATOR SPECIFICATIONS TYPE ....................................................................... Four-pole, revolving field ROTOR INSULATION ....................................................................... Class F STATOR INSULATION ...................................................................... Class H VOLTAGE WAVE FORM DEVIATION .................................................... <5% TOTAL HARMONIC DISTORTION (line to line) .................................... <3% TELEPHONE INTERFERENCE FACTOR (TIF) ..................................... <50 ALTERNATOR ................................................. Self-ventilated and drip-proof BEARINGS (PRE-LUBED & SEALED) ....................................................... 1 COUPLING .................................................................... Direct, Flexible Disc LOAD CAPACITY (STANDBY) ............................................................. 100% NOTE: Emergency loading in compliance with NFPA 99, NFPA 110, paragraph 5-13.2.6. Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards. EXCITATION SYSTEM DIRECT .................................................................. DC excitation system > Low-velocity brushes and slip rings > VOLTAGE REGULATION ........................................................ Solid-state > ±1% regulation > GENERATOR FEATURES ?Four pole, revolving field generator, directly connected to the engine shaft through a heavy-duty, flexible disc for permanent alignment. ?Generator meets temperature rise standards for class "F" insulation as defined by NEMA MG1-22, while the insulation system meets the requirements for the higher class "H" rating. ?Stator windings are "trickle" varnished and rotor windings are "roll-dipped" for complete impregnation. ?Unit tested for motorstarting ability by measuring instantaneous voltage dip with a waveform data acquisition system. ?All models utilize an advanced wire harness design for reliable interconnection within the circuitry. ?Magnetic circuit, including amortisseur windings, tooth and skewed stator design, provides a minimal level of waveform distortion and an electromagnetic interference level which meets accepted requirements for standard AM radio, TV, and marine radio telephone applications. ?Voltage waveform deviation, total harmonic content of the AC waveform, and balanced T.I.F. (Telephone Influence Factor) have been evaluated to acceptable standards in accordance with NEMA MG1-22. ?Alternator is of drip-proof guarded construction. ?Fully life-tested protective systems, including "field circuit and thermal overload protection" and standard mainline circuit breakers capable of handling full output capacity. ?System torsional acceptability confirmed during prototype testing. ENGINE SPECIFICATIONS MAKE ............................................................................ FORD INDUSTRIAL MODEL ............................................................................................... 2.5FG CYLINDERS ..................................................................................... 4 in-line DISPLACEMENT ......................................................... 2.5 Liter (153 cu. in.) BORE ............................................................................. 96.01 mm (3.78 in.) STROKE .......................................................................... 86.36 mm (3.4 in.) COMPRESSION RATIO ...................................................................... 9.37:1 INTAKE AIR ................................................................... Naturally Aspirated NUMBER OF MAIN BEARINGS ................................................................ 5 CONNECTING RODS .................................................... 4-Drop forged steel CYLINDER HEAD ........................................................................... S.O.H.C. PISTONS .......................................................................... 4-Aluminum Alloy CRANKSHAFT ................................................................ Drop Forged Steel VALVE TRAIN LIFTER TYPE .................................................................... Rocker Arm Type INTAKE VALVE MATERIAL ......................... High Temperature Alloy Forged EXHAUST VALVE MATERIAL ..................... High Temperature Alloy Forged VALVE SEATS ........................................................................... Replaceable ENGINE GOVERNOR . ELECTRONIC.............................................................................. Standard FREQUENCY REGULATION, NO-LOAD TO FULL LOAD ............ 0.5% STEADY STATE REGULATION .................................................. ±0.25% LUBRICATION SYSTEM TYPE OF OIL PUMP ............................................................................ Gear OIL FILTER ...................................................................... Full flow, cartridge CRANKCASE CAPACITY .................................................. 3.8 Liters (4 qts.) COOLING SYSTEM TYPE OF SYSTEM ........................................ Pressurized, closed recovery WATER PUMP .......................................................... Pre-lubed, self-sealing TYPE OF FAN ................................................................................... Pusher NUMBER OF FAN BLADES ....................................................................... 6 DIAMETER OF FAN ......................................................... 406 mm (16.0 in.) FUEL SYSTEM FUEL . Natural Gas or L.P. Vapor .......................................................... Standard CARBURETOR ............................................................................ Down draft SECONDARY FUEL REGULATOR - Nat. Gas or L.P. Vapor Systems AUTOMATIC FUEL LOCKOFF SOLENOID ................................... Standard OPERATING FUEL PRESSURE VAPOR SYSTEMS ..Nat. Gas 5 to 14" H2O LP Vapor.....11" to 14" H2O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR ................................... 15 Amps at 12 V STARTER MOTOR .................................................................................. 12 V RECOMMENDED BATTERY ............... 12 V, 525 CCA @ 0o F/75 A.H., 26R GROUND POLARITY ..................................................................... Negative APPLICATION & ENGINEERING DATA Home Standby - 15, 20 & 25 Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. |
| STANDBY | ||||||
| GENERATOR OUTPUT VOLTAGE/KW - 60Hz | HS-15 | HS-20 | HS-25 | |||
| NG/LP | Rated AMP | NG/LP | Rated AMP | Rated NG/LP AMP | ||
| 120/240V, 1-phase, 1.0 pf | 15 | 62.5 | 20 | 83.3 | 25 104.2 | |
| MOTORSTARTING Maximum at 35% instantaneous voltage dip with standard alternator; 60 Hz | 29 KVA | 38 KVA | 50 KVA | |||
| FUEL Fuel consumption – 60 Hz – 100% Load | N.G. | L.P. | N.G. | L.P. | N.G. L.P. | |
| ft.3 /hr. (gal./hr.) m3 /hr. | 236 NA 6.68 | 92 2.53 2.6 | 307 NA 8.69 | 122 3.35 3.45 | 375 150 NA 4.12 10.62 4.25 | |
| COOLING Coolant capacity System lit.(US gal.) Engine lit.(US gal.) Radiator lit.(US gal.) Coolant flow/min. 60 Hz lit.(US gal.) Heat rejection to coolant 60 Hz BTU/hr. Cooling air flow 60 Hz m3/min. (cfm) COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz m3/min. (cfm) | 11.4 (3.0) 5.3 (1.4) 6.1 (1.6) 67.8 (17.9) 66,000 963 (4200) 1.4 (50) | 11.4 (3.0) 5.3 (1.4) 6.1 (1.6) 67.8 (17.9) 88,000 963 (4200) 1.8 (64) | 11.4 (3.0) 5.3 (1.4) 6.1 (1.6) 67.8 (17.9) 110,000 963 (4200) 2.1 (75) | |||
| EXHAUST Exhaust flow at rated output 60 Hz m3/min. (cfm) Max. recommended back pressure Kpa (Hg) Exhaust temp. at rated output °C (°F) Exhaust outlet size N.P.T. (female) | 3.4 (120) 5.0 (1.5”) 449 (840) 1.5” | 4.8 (168) 5.0 (1.5”) 516 (960) 1.5” | 5.9 (210) 5.0 (1.5”) 566 (1050) 1.5” | |||
| ENGINE Rated at RPM 60 Hz HP at rated KW 60 Hz Piston speed 60 Hz m/min. (ft./min.) BMEP (PSI) 60 Hz | 1800 26 310 (1020) 76 | 1800 34 310 (1020) 99 | 1800 43 310 (1020) 125 | |||
| POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature -1.65% for every 10°F above - °F Altitude -3% for every 1000 ft. above - ft. | 77 600 | 77 600 | 77 600 | |||
| SOUND OUTPUT In dB(A) at 23 feet with generator operating at full load | 68.7 | 70.7 | 70.7 |
STANDARD ENGINE & SAFETY FEATURES Home Standby - 15, 20 & 25
- High Coolant Temperature Automatic Shutdown - Battery Charge Alternator
- Low Coolant Level Automatic Shutdown - Battery Cables
- Low Oil Pressure Automatic Shutdown - Battery Tray
- Overspeed Automatic Shutdown (Solid-state) - Vibration Isolation of Unit to Mounting Base
- Crank Limiter (Solid-state) - 12 Volt, Solenoid-Activated Starter Motor
- Oil Drain Extension - Air Cleaner
- Radiator Drain Extension - Fan Guard
- Factory-Installed Cool Flow Radiator - Control Console
- Closed Coolant Recovery System - UV/Ozone Resistant Hoses
- Isochronous Governor - Stainless Steel Flexible Exhaust Connection
- Rubber-Booted Engine Electrical Connections - Flexible Fuel Line
- Fuel Lockoff Solenoid - Critical Exhaust Silencer
- Secondary Fuel Regulator (N.G. and L.P.) - Battery Trickle Charger
- Weather Protective Enclosure (Locking Type) - Main Line Circuit Breaker
Home Standby Control Features:
Home Standby Control Home Standby Microprocessor Distributed by: Console Controls
Manual/Auto/Off switch Automatic voltage regulation
Six light LED indicator for Utility voltage sensinggenerator status and Utility interrupt delayfault status (10-second setpoint)
Fuses (panel overload) Engine warm-upSet exercise time switch (10-second setpoint)Engine cool-down(1-minute setpoint) Seven-day exerciser
Design and specifications
subject to change without notice.
Dimensions shown are approximate. 15 kW UNIT WEIGHT: 923 lbs.
Contact your Generac dealer for certified drawings.

20 kW UNIT WEIGHT: 942 lbs.
DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES
25 kW UNIT WEIGHT: 998 lbs.
1783.1 70.2
1836.8 72.3
958 37.7
Overall Height = 39 inches
76.2 3.0
Overall Length = 72.3 inches
All specifications are subject to change without notice.