Generac Guardian QuietSource Home Standby - 11kW Generator Set  Power Rating Model # 04916
Single Phase Generators


Home  |  email  |  1-866-734-3735 Toll Free Toll Free  |  Buy Commercial Generators Online

Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches   |  Pricing  |  Email

UPDATE:Generac has discontinued this model, 
please see available generators by clicking here.

 

 

 

Air-Cooled Gas Backup Emergency Power Engine Generator Set

Continuous Standby Power Rating Model # 04916 -11kW LPG 60Hz 10kW NG 60Hz

INCLUDES:

  • Composite Mounting Pad
  • Natural Gas or LP Gas Operation
  • GFCI external duplex outlet
  • 12Vdc internal outlet
  • Flexible Fuel Line
  • UL 2200 Listed

     

FEATURES

INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that theses ystems will provide superior performance. TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITYSOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.

SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM.

GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility

HOME STANDBY SPECIFICATIONS QuietSource Home Standby - 11kW

ENGINE •Generac (OHVI) Design •”Spiny-lok” cast iron cylinder walls •Electronic ignition, spark advance and compression release •Full pressure lubrication system •Low oil pressure shutdown system •High temperature shutdown Maximizes engine “breathing” for increased fuel efficiency. Cylinder walls run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. Superior shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating.
GENERATOR•Revolving field •Skewed stator •Displaced phase excitation •Automatic voltage regulation •UL 2200 Listed Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Provides more surge capability than brushless generator designs. Regulates the output voltage to ±2% prevents damaging voltage spikes. For your safety
TRANSFERSWITCHNot included with this model
MICROPROCESSOR CONTROL •Manual/Auto/Off switch •Utility voltage sensing •Utility interrupt delay •Engine warm-up •Engine cool-down •Seven day exerciser •Timed Trickle Battery charger •Main Line Circuit Breaker •Six LED status indicator lights Selects the operating mode. Constantly monitors utility voltage, setpoints 60% dropout, 70% pick-up, of standard voltage. Prevents nuisance start-ups of the engine, set point approximately 10 seconds. Ensures engine is ready to assume the load, setpoint approximately 10 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages. Maintains battery amperage to insure starting. Protects generator from overload. Allows monitoring of generator condition in the event of generator shutdown or system readiness.
UNIT •Aluminum weather protective enclosure •Enclosed critical grade muffler •Small, compact, attractive •1’ Flexible Fuel Line •Composite Mounting Pad •UL Listed Ensures protection against mother nature. Fights corrosion even in the most severe environments. Electrostatically applied epoxy paint for added durability. Hinged key locking roof panel for security. Gas support lifts on roof panel for convenience. Engineered air-channeling design reduces sound output to level equal to that of normal conversation. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. For connection between rigid pipe and generator fuel inlet. Absorbs vibration during operation. Eliminates the need to pour a concrete base. For your safety and assurance of full rated power output.

Home Standby Generator - 11kW 11,000 Watts

GENERATOR Model 04916 (11kW)

Rated Maximum Continuous Power Capacity (LPG)...................................................................................................... 11,000 Watts*

Rated Maximum Continuous Power Capacity (NG)......................................................................................................... 10,000 Watts*

Rated Voltage........................................................................................................................................................................120/240

Rated Maximum Continuous Load Current

120 Volts .................................................................................................................................................................................70.8

240 Volts ................................................................................................................................................................................ 35.4

Main Line Circuit Breaker .................................................................................................................................................... 50 Amp

Phase ........................................................................................................................................................................................1

Number of Rotor Poles ............................................................................................................................................................. 2

Rated AC Frequency ............................................................................................................................................................. 60Hz

Power Factor .............................................................................................................................................................................1

Battery Requirement (not included) ............................................................................................................................... Group 26/26R

12 Volts and

550 Cold-cranking

Amperes Minimum

Shipping Weight (Includes Transfer Switch) .............................................................................................................. Approx. 495 Pounds

Dimensions (L” x W” x H”)................................................................................................................................................ 48 x 39 x 31

Sound Output in dB(A) at 23 ft. with generator operating at full load .................................................................................... 62.2

ENGINE Model 04916 (11kW)

Type of Engine....................................................................................................................................................... GENERAC OHVI V-TWIN

Number of Cylinders.................................................................................................................................................................. 2

Rated Horsepower............................................................................................................................................................30 @3,600 rpm

Displacement......................................................................................................................................................................... 992cc

Cylinder Block.............................................................................................................................................................. Aluminum w/Cast

Iron Sleeve

Valve Arrangement........................................................................................................................................................ Overhead Valve

Ignition System........................................................................................................................................................ Solid-state w/Magneto

Compression Ratio................................................................................................................................................................ 9.5:1

Starter................................................................................................................................................................................... 12 Vdc

Oil Capacity Including Filter........................................................................................................................................... Approx. 1.7 Qts.

Engine RPM / Alternator RPM....................................................................................................................................... 2,700 / 3600

Fuel Consumption

Natural Gas..............................................cu.ft./hr.

.................................................................1/2 Load.......................................................................................................... 115

................................................................Full Load.......................................................................................................... 202

Liquid Propane Gas...............................ft3/hr(gal/hr)

................................................................1/2 Load ..................................................................................................... 55.6 (1.52)

................................................................Full Load .................................................................................................... 86.4 (2.37)

CONTROLS Model 04916 (11kW)

Model Switch

-Auto ........................................................................................................................................................... Automatic Start on Utility

failure/7 day exerciser

-Off .......................................................................................................................................................... Stops unit. Power is removed

Control and charger still operate

-Manual/Test (start) ................................................................................................................................ Start with starter control, unit

stays on. If utility fails, transfer

to load takes place.

Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest

(90 sec. maximum duration)

Engine Warm-up .............................................................................................................................................................. 10 seconds

Engine Cool-Down ............................................................................................................................................................. 1 minute

Starter Lock-out ............................................................................................................................................... Starter cannot re-engage until

5 sec. after engine has stopped.

2.5 Amp Timed Trickle Battery Charger ............................................................................................................................ Standard

Automatic Voltage Regulator w/Overvoltage Protection .................................................................................................... Standard

Automatic Low Oil Pressure Shutdown ............................................................................................................................. Standard

Overspeed Shutdown .................................................................................................................................................. Standard, 72Hz

High Temperature Shutdown ............................................................................................................................................ Standard

Overcrank Protection ....................................................................................................................................................... Standard

Safety Fuse ..................................................................................................................................................................... Standard

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,

ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power

decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F).

Home Standby - 11kW

NOTE: The fuel system operates ONLY

on gaseous fuels.

Required fuel pressure:

Natural gas: 5 to 7 “ of water column

Liquid propane gas: 11 to 14” of

water column

 

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F).

FRONT VIEW 76.2 [3.00"]RIGHT SIDE VIEW REAR VIEW

QuietSource Home Standby - 11kW

AIR INTAKE

AIROUTLET 914mm [ 36.0" ]

914mm [ 36.0" ]

MINIMUM OPEN AREA

ALL AROUND UNIT

1219

[47.98"]

826

[32.54"]

SWING ARC OF SERVICE DOOR

1797 [70.76"] TOP VIEW
(WITH ROOF OPEN)

3/4" NPT FUEL INLET GAS PRESSURE OF

5-7" WATER COLUMN REQUIRED FOR NG FUEL,

ACCESS TO OUTPUT CIRCUIT 11-14" REQUIRED FOR LP FUEL

BREAKER AND TRANSFER SWITCH CONNECTIONS  DO NOT LIFT BY THE ROOF

(REMOVE PLUG FOR ACCESS) 790 [31.09"] 468 [18.43"] GROUNDING LUG GROUNDING LUG 1219 [48.00"] 914 [36.00"] 457

LIFTING HOLES 4-CORNERS [18.00"] 76.2 [3.00"]

PEA GRAVEL

MINUMUM (SERVICE DOOR OPEN)

**ALL DIMENSIONS IN: MILLIMETERS [INCHES]

 

GENERAC POWER SYSTEMS  |  

All specifications are subject to change without notice.

Generac Guardian QuietSource Home Standby - 
11kW Generator Set 
Power Rating Model # 04916

Continuous Standby Power Rating Model 04916 -11kW LPG 60Hz 10kW NG 60Hz