Generac Guardian Elite 55 kW 55000 watt generator liquid cooled

1-866-734-3735 Toll Free

55 kW 55,000 Watt Generator Generac Guardian Elite
Click here to purchase this generator at a discount

>Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches


Home  |  email  |  1-866-734-3735 Toll Free

30kW - 3.0L Liquid Cooled 40kW - 3.9L Liquid Cooled 50kW - 3.0L Liquid Cooled 55kW - 5.4L Liquid Cooled 70kW - 3.9L Liquid Cooled 70kW - 6.8L Liquid Cooled 80kW - 5.4L Liquid Cooled 100kW - 5.4L Liquid Cooled 100kW - 6.8L Liquid Cooled 130kW - 6.8L Liquid Cooled 150kW - 6.8L Liquid Cooled 11 kW 15, 20 & 25 kW 30 kW & 40 kWTransfer Switches  |  Generator Control Panel


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55 kW

OPERATING DATA

COMMERCIAL 50 kW
KW RATING 55
ENGINE SIZE 5.4 Liter V-8
GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 3.0 pf 277/480V, 3-phase, 3.0 pf KW 55 55 55 AMP 229 191 83 CB Size 250 200 90
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208 3-phase 480V 3-phase 115 130
ENGINE FUEL CONSUMPTION (Natural Gas) Exercise cycle ft3/hr. 25% of rated load ft3/hr. 50% of rated load ft3/hr. 75% of rated load ft3/hr. 100% of rated load ft3/hr. 128 204 392 547 756
ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. Coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator ˚C (˚F) Max. ambient temperature ˚C (˚F) 4510 2.5 231,000 60 (150) 50 (140)
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 165
SOUND EMISSIONS IN DBA Exercising at 7 meters Full load at 7 meters 59 73
EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet ˚F 438 925
ENGINE PARAMETERS Rated synchronous RPM 60 Hz HP at rated KW 60 Hz 1800 88
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 ˚C above - ˚C 1.65% for every 10 ˚F above - ˚F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 25 77 182 600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. KW rating is based on LPG Fuel and may derate with natural gas.

INTERCONNECTIONS 55 kW NON-TERMINATED INSTALLATION LAYOUT

UNIT WEIGHT 1973 LBS.

Copyright 2005 Bestgenerators.com

55 kW 55,000 Watt Generator Generac Guardian Elite  Click here to purchase this generator at a discount

 