Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches

Home Standby Generator Power Rating 80 kW 60 Hz Call Toll Free
1-866-734-3735

Liquid Cooled Gas Engine Generator Sets
Click here to purchase this generator at a discount


Home  |  email  |  1-866-734-3735 Toll Free Toll Free  |  Buy Commercial Generators Online

30kW - 3.0L Liquid Cooled 40kW - 3.9L Liquid Cooled 50kW - 3.0L Liquid Cooled 55kW - 5.4L Liquid Cooled 70kW - 3.9L Liquid Cooled 70kW - 6.8L Liquid Cooled 80kW - 5.4L Liquid Cooled 100kW - 5.4L Liquid Cooled 100kW - 6.8L Liquid Cooled 130kW - 6.8L Liquid Cooled 150kW - 6.8L Liquid Cooled 11 kW 15, 20 & 25 kW 30 kW & 40 kWTransfer Switches  |  Generator Control Panel

Home Standby Generator Power Rating 80 kW 60 Hz

UL 2200 Listed 

Generac 5.4L Engine Naturally Aspirated Gaseous Fueled
 

STANDARD EQUIPMENT

FEATURES

  • Watertight state of the art electrical connectors
  • Mainline circuit breaker
  • Oil drain extension to frame rail
  • Radiator drain extension
  • Battery charge alternator
  • 2 Amp static battery charger
  • Battery and battery cables
  • Battery rack
  • Fan and belt guards
  • Isochronous governor
Innovative design and fully prototype tested Built-in kW, kVAR and power factor meters
UL2200 Listed Watertight electrical connectors
Solid state frequency compensated digital Rodent proof construction
voltage regulator High efficiency, low distortion Generac designed alternator
Dynamic and static battery charger Vibration isolated from mounting base
Sound attenuated acoustically designed enclosure Matching Generac transfer switches engineered and
Quiet test for low noise level exercise tested to work as a system
Acoustically designed engine cooling system All components easily accessible for maintenance
High flow low noise factory engineered exhaust system Electrostatically applied powder paint
State of the art digital control system H-100 microprocessor control panel
Guardian Elite Logo

APPLICATION & ENGINEERING DATA 70 kW

GENERATOR SPECIFICATIONS

TYPE ..........................................................................................................Synchronous

ROTOR INSULATION ..........................................................................................Class H

STATOR INSULATION ........................................................................................Class H

TOTAL HARMONIC DISTORTION ........................................................................<3.5%

TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50

ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire

BEARINGS ....................................................................................................Sealed Ball

COUPLING ....................................................................................................Gear Drive

LOAD CAPACITY (STANDBY RATING) ................................................................80 kW

EXCITATION SYSTEM ....................................................................................Brushless

NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,

paragraph 5-13.2.6. Generator rating and performance in accordance

with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.

GENERATOR FEATURES

Revolving field heavy duty generator

Directly connected to the engine

Operating temperature rise 120 °C above a 40 °C ambient

Insulation is Class H rated at 150 °C rise

All prototype models have passed three phase short circuit testing

VOLTAGE REGULATOR

TYPE ..............................................................................................................Full Digital

SENSING ............................................................................................................3 Phase

REGULATION ......................................................................................................± 1/4%

FEATURES ......................................................................Built into H-100 Control Panel

V/F Adjustable

Adjustable Voltage and Gain

CONTROL PANEL FEATURES

TWO FOUR LINE LCD DISPLAYS READ:

Voltage (all phases) Current (all phases)

Power factor kW

kVAR Transfer switch status

Engine speed Low fuel pressure

Run hours Service reminders

Fault history Oil pressure

Coolant temperature Time and date

Low oil pressure shutdown High coolant temperature shutdown

Overvoltage Overspeed

Low coolant level Low coolant level

Not in auto position (flashing light)

INTERNAL FUNCTIONS:

I2T function for alternator protection from line to neutral and line to line short circuits

Emergency stop

Programmable auto crank function

2 wire start for any transfer switch

Communicates with the Generac HTS transfer switch

Built-in 7 day exerciser

Adjustable engine speed at exerciser

RS232 port for GenLink® control

RS485 port remote communication

Canbus addressable

Governor controller and voltage regulator are built into the master control board

Temperature range -40 °C to 70 °C

ENGINE SPECIFICATIONS

MAKE ................................................................................................................ Generac

MODEL..................................................................................................................V Type

CYLINDERS ..................................................................................................................8

DISPLACEMENT ................................................................................................5.4 Liter

BORE ........................................................................................................................3.55

STROKE....................................................................................................................4.17

COMPRESSION RATIO ..............................................................................................9:1

INTAKE AIR SYSTEM........................................................................Naturally Aspirated

VALVE SEATS ..................................................................................................Hardened

LIFTER TYPE ....................................................................................................Hydraulic

GOVERNOR SPECIFICATIONS

TYPE ................................................................................................................Electronic

FREQUENCY REGULATION ..................................................................................± 1%

STEADY STATE REGULATION ............................................................................± 1/2%

ADJUSTMENTS

Speed......................................................................................................Yes

Droop ......................................................................................................Yes

ENGINE LUBRICATION SYSTEM

OIL PUMP ................................................................................................................Gear

OIL FILTER ..........................................................................................Full flow cartridge

CRANKCASE CAPACITY ..................................................................................5 Quarts

ENGINE COOLING SYSTEM

TYPE ....................................................................................................................Closed

WATER PUMP ................................................................................................Belt driven

FAN SPEED..............................................................................................................2100

FAN DIAMETER................................................................................................22 inches

FAN MODE..............................................................................................................Puller

FUEL SYSTEM

FUEL TYPE....................................................................................................Natural gas

CARBURETOR ..............................................................................................Down Draft

SECONDARY FUEL REGULATOR ..................................................................Standard

FUEL SHUT OFF SOLENOID ..........................................................................Standard

OPERATING FUEL PRESSURE..................................................................5” - 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp

STATIC BATTERY CHARGER........................................................................12V 2 Amp

RECOMMENDED BATTERY ......................................................................24F 625CCA

SYSTEM VOLTAGE ............................................................................................12 Volts

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

80 kW Generator OPERATING DATA

COMMERCIAL 80 kW
KW RATING 80
ENGINE SIZE 5.4 Liter V-8
GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 3.0 pf 277/480V, 3-phase, 3.0 pf KW 80 80 80 AMP 333 278 120 CB Size 350 300 150
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208 3-phase 480V 3-phase 160 185
ENGINE FUEL CONSUMPTION (Natural Gas) Exercise cycle ft3/hr. 25% of rated load ft3/hr. 50% of rated load ft3/hr. 75% of rated load ft3/hr. 100% of rated load ft3/hr. 185 297 571 795 1100
ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. Coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator ˚C (˚F) Max. ambient temperature ˚C (˚F) 5200 4.0 304,000 60 (150) 50 (140)
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 240
SOUND EMISSIONS IN DBA Exercising at 7 meters Full load at 7 meters 61 74
EXHAUST Exhaust flow at rated output 60 Hz m3/min. (cfm) Exhaust temp. at muffler outlet ˚F 691 925
ENGINE PARAMETERS Rated synchronous RPM 60 Hz HP at rated KW 60 Hz 2650 125
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 ˚C above - ˚C 1.65% for every 10 ˚F above - ˚F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 25 77 182 600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kW rating is based on LPG fuel and may derate with natural gas.

INTERCONNECTIONS Diagram 80 kW Generator Generac Guardian Elite Liquid Cooled Model

INTERCONNECTIONS Diagram 80 kW Generator Generac Guardian Elite Liquid Cooled Model

NON-TERMINATED

INSTALLATION LAYOUT Diagram 80 kW Generator Generac Guardian Elite Liquid Cooled Model

INSTALLATION LAYOUT Diagram 80 kW Generator Generac Guardian Elite Liquid Cooled Model

UNIT WEIGHT 2573 LBS.

GENERAC® POWER SYSTEMS

Home