Quiet-Test Mode For Low Noise Exercise -60 dB(A) at 23 feetGenerac 3.0L Engine Naturally Aspirated Gaseous Fueled| STANDARD EQUIPMENT | |||
| • | All input connections in one single area | • | Watertight state of the art electrical connectors |
| • | High coolant temperature shutdown | • | Mainline circuit breaker |
| • | Low oil pressure shutdown | • | Radiator drain extension |
| • | Low coolant level automatic shutdown | • | Battery charge alternator |
| • | Overspeed automatic shutdown | • | 2 Amp static battery charger |
| • | Crank timer | • | Battery and battery cables |
| • | Exercise timer | • | Battery rack |
| • | Oil drain extension | • | Fan and belt guards |
| • | Cool flow radiator | • | Isochronous governor |
| • | Closed coolant recovery system | ||
| • | UV/Ozone resistant hoses | ||
|
FEATURES |
|||
| • | Innovative design and fully prototype tested | • | State of the art digital control system |
| • | UL2200 Listed | • | Watertight electrical connectors |
| • | Solid state frequency compensated digital | • | Rodent proof construction |
| voltage regulator | • | High efficiency, low distortion Generac designed alternator | |
| • | Dynamic and static battery charger | • | Vibration isolated from mounting base |
| • | Sound attenuated acoustically designed enclosure | • | Matching Generac transfer switches engineered and |
| • | Quiet test for low noise level exercise | tested to work as a system | |
| • | Acoustically designed engine cooling system | • | All components easily accessible for maintenance |
| • | High flow low noise factory engineered exhaust system | • | Electrostatically applied powder paint |
| • | R100 digital control panel |
ROTOR INSULATION ..........................................................................................Class H
STATOR INSULATION ........................................................................................Class H
TOTAL HARMONIC DISTORTION ........................................................................<3.5%TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50
ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire
BEARINGS ....................................................................................................Sealed Ball
COUPLING ..................................................................................................Flexible Disc
LOAD CAPACITY (STANDBY RATING) ................................................................30 kW
EXCITATION SYSTEM............................................................................................Direct NOTE: Generator rating and performance in accordance with ISO8528-5,BS5514, SAE J1349, ISO3046, and DIN6271 standards.GENERATOR FEATURES Revolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120 °C above a 40 °C ambientInsulation is Class H rated at 150 °C riseAll models are fully prototyped tested VOLTAGE REGULATOR TYPE ................................................................................................................ElectronicSENSING ....................................................................................................Single PhaseREGULATION ..........................................................................................................± 1%FEATURES................................................................................................V/F AdjustableAdjustable Voltage and GainLED Indicators CONTROL PANEL FEATURES SIX LED INDICATOR LIGHTS:Overcrank shutdown Overspeed shutdownLow coolant level shutdown High coolant temperature shutdownLow oil pressure shutdown Low battery voltageSystem ready for operation No utility sensingExerciser not set (in auto mode only) Low fuel pressureDelay on utility failure for engine start Engine warmup before transferDelay to retransfer to utility Delay to retransfer to utilityEngine cooldown timerINTERNAL FUNCTIONS:3 position switch (auto, off and manual)2 wire start for any transfer switchCommunicates with the Generac RTS transfer switchBuilt-in 7 day exerciserSelectable engine speed at exerciseGovernor controller is built into the master control boardTemperature range -40 °C to 70 °C ENGINE SPECIFICATIONS MAKE ................................................................................................................ GeneracMODEL..................................................................................................................V TypeCYLINDERS ..................................................................................................................6
DISPLACEMENT ................................................................................................3.0 Liter
BORE ........................................................................................................................3.55
STROKE......................................................................................................................3.1
COMPRESSION RATIO ..........................................................................................9.3:1
INTAKE AIR SYSTEM........................................................................Naturally Aspirated
VALVE SEATS ..................................................................................................Hardened
LIFTER TYPE ....................................................................................................Hydraulic
GOVERNOR SPECIFICATIONS TYPE ................................................................................................................Electronic
FREQUENCY REGULATION ..................................................................................± 1%STEADY STATE REGULATION ............................................................................± 1/2%
ADJUSTMENTSSpeed......................................................................................................Yes
Droop ......................................................................................................Yes
ENGINE LUBRICATION SYSTEM OIL PUMP ................................................................................................................GearOIL FILTER ..........................................................................................Full flow cartridge
CRANKCASE CAPACITY ..................................................................................4 Quarts
ENGINE COOLING SYSTEM TYPE ....................................................................................................................Closed
WATER PUMP ................................................................................................Belt driven
FAN SPEED..............................................................................................................1800
FAN DIAMETER................................................................................................18 inches
FAN MODE............................................................................................................Pusher
FUEL SYSTEM FUEL TYPE ..........................................................................Natural gas, propane vapor
CARBURETOR ..............................................................................................Down Draft
SECONDARY FUEL REGULATOR ..................................................................Standard
FUEL SHUT OFF SOLENOID ..........................................................................Standard
OPERATING FUEL PRESSURE..................................................................5” - 14” H2O
ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp
STATIC BATTERY CHARGER ..............................................................................2 Amp
RECOMMENDED BATTERY ......................................................................24F 625CCASYSTEM VOLTAGE ............................................................................................12 Volts
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
|
COMMERCIAL 30 kW |
||||
|
KW RATING |
30 |
|||
|
ENGINE SIZE |
3.0 Liter V-6 |
|||
|
GENERATOR OUTPUT VOLTAGE/KW - 60Hz |
KW |
AMP |
CB Size |
|
|
120/240V, 1-phase, 1.0 pf |
30 |
125 |
150 |
|
|
120/208V, 3-phase, 3.0 pf |
30 |
104 |
125 |
|
|
277/480V, 3-phase, 3.0 pf |
30 |
45 |
50 |
|
|
GENERATOR LOCKED ROTOR KVA |
||||
|
AVAILABLE @ VOLTAGE DIP OF 35% |
||||
|
Single phase or 208 3-phase |
60 |
|||
|
480V 3-phase |
70 |
|||
|
ENGINE FUEL CONSUMPTION (Natural Gas) |
||||
|
Exercise cycle |
ft3/hr. |
70 |
||
|
25% of rated load |
ft3/hr. |
111 |
||
|
50% of rated load |
ft3/hr. |
214 |
||
|
75% of rated load |
ft3/hr. |
298 |
||
|
100% of rated load |
ft3/hr. |
412 |
||
|
ENGINE COOLING |
||||
|
Air flow (inlet air including alternator and combustion air) |
ft3/min. |
2460 |
||
|
Coolant capacity |
US gal. |
2.5 |
||
|
Heat rejection to coolant |
BTU/hr. |
115,000 |
||
|
Max. operating air temp. on radiator |
°C (°F) |
60 (150) |
||
|
Max. ambient temperature |
°C (°F) |
50 (140) |
||
|
COMBUSTION AIR REQUIREMENTS |
||||
|
Flow at rated power 60 Hz |
cfm |
92 |
||
|
SOUND EMISSIONS IN DBA |
||||
|
Exercising at 7 meters |
60 |
|||
|
Full load at 7 meters |
73 |
|||
|
EXHAUST |
||||
|
Exhaust flow at rated output 60 Hz |
cfm |
240 |
||
|
Exhaust temp. at muffler outlet |
°F |
925 |
||
|
ENGINE PARAMETERS |
||||
|
Rated synchronous RPM |
60 Hz |
1800 |
||
|
HP at rated KW |
60 Hz |
48 |
||
|
POWER ADJUSTMENT FOR AMBIENT CONDITIONS |
||||
|
Temperature Deration |
||||
|
3% for every 10 °C above - °C |
25 |
|||
|
1.65% for every 10 °F above - °F |
77 |
|||
|
Altitude Deration |
||||
|
1% for every 100 m above - m |
183 |
|||
|
3% for every 1000 ft. above - ft. |
600 |
|||
30 kW
120 Volt +
Neutral
CONNECTION BOX
Grd
To Generator Control Panel
FRAME RAIL
CIRCUIT BREAKER SIZE KW VOLTS / AMPS LUG SIZE 30 240 1 Ø 150 #6 to 350 mcm
Ground Level 30 208 3 Ø 125 #6 to 350 mcm Concrete Slab STUB-UP AREA 30 480 3 Ø 45 #10 to 1/0See Install Dwg for Dimensions
INSTALLATION LAYOUT

Single Phase Generators Standby Power Rating 30 kW 60 Hz Liquid Cooled Gas Engine Generator Sets