130 kW 60 Hz Standby Power Rating
Liquid Cooled Gas Engine Generator Sets
Click here to purchase this generator at a discount

Quiet-Test Mode  For Low Noise Exercise -61 dB(A) at 23 feet

Home  |  email  |  1-866-734-3735 Toll Free Toll Free  |  Buy Commercial Generators Online

Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches   |  Pricing  |  Email

 

Guardian Elite 130 KW Commercial Power Generator

130 kW Standy Power Rating Generac Home Generator Set with 6.8L Engine

Naturally Aspirated Gaseous Fueled

UL 2200 Listed

STANDARD EQUIPMENT

  • All input connections in one single area
  • High coolant temperature shutdown
  • Low oil pressure shutdown
  • Low coolant level automatic shutdown
  • Overspeed automatic shutdown
  • Adjustable cranking timer
  • Adjustable exercise timer
  • Oil drain extension
  • Cool flow radiator
  • Closed coolant recovery system
  • UV/Ozone resistant hoses

FEATURES

  • Watertight state of the art electrical connectors
  • Mainline circuit breaker
  • Oil drain extension to frame rail
  • Radiator drain extension
  • Battery charge alternator
  • 2 Amp static battery charger
  • Battery and battery cables
  • Battery rack
  • Fan and belt guards
  • Isochronous governor

     

Innovative design and fully prototype tested Built-in kW, kVAR and power factor meters
UL2200 Listed Watertight electrical connectors
Solid state frequency compensated digital Rodent proof construction
voltage regulator High efficiency, low distortion Generac designed alternator
Dynamic and static battery charger Vibration isolated from mounting base
Sound attenuated acoustically designed enclosure Matching Generac transfer switches engineered and
Quiet test for low noise level exercise tested to work as a system
Acoustically designed engine cooling system All components easily accessible for maintenance
High flow low noise factory engineered exhaust system Electrostatically applied powder paint
State of the art digital control system H-100 microprocessor control panel
Guardian Elite Commercial 3 phase generators by Generac Power Systems

GENERATOR SPECIFICATIONS

TYPE ..........................................................................................................Synchronous

ROTOR INSULATION ..........................................................................................Class H

STATOR INSULATION ........................................................................................Class H

TOTAL HARMONIC DISTORTION ........................................................................<3.5%

TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50

ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire

BEARINGS ....................................................................................................Sealed Ball

COUPLING ....................................................................................................Gear Drive

LOAD CAPACITY (STANDBY RATING) ..............................................................130 kW

EXCITATION SYSTEM ....................................................................................Brushless

NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,

paragraph 5-13.2.6. Generator rating and performance in accordance

with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.

GENERATOR FEATURES

Revolving field heavy duty generator

Quiet drive coupling

Operating temperature rise 120 °C above a 40 °C ambient

Insulation is Class H rated at 150 °C rise

All prototype models have passed three phase short circuit testing

VOLTAGE REGULATOR

TYPE ..............................................................................................................Full Digital

SENSING ............................................................................................................3 Phase

REGULATION ......................................................................................................± 1/4%

FEATURES ......................................................................Built into H-100 Control Panel

V/F Adjustable

Adjustable Voltage and Gain

CONTROL PANEL FEATURES

TWO FOUR LINE LCD DISPLAYS READ:

Voltage (all phases) Current (all phases)

Power factor kW

kVAR Transfer switch status

Engine speed Low fuel pressure

Run hours Service reminders

Fault history Oil pressure

Coolant temperature Time and date

Low oil pressure shutdown High coolant temperature shutdown

Overvoltage Overspeed

Low coolant level Low coolant level

Not in auto position (flashing light)

INTERNAL FUNCTIONS:

I2T function for alternator protection from line to neutral and line to line short circuits

Emergency stop

Programmable auto crank function

2 wire start for any transfer switch

Communicates with the Generac HTS transfer switch

Built-in 7 day exerciser

Adjustable engine speed at exerciser

RS232 port for GenLink® control

RS485 port remote communication

Canbus addressable

Governor controller and voltage regulator are built into the master control board

Temperature range -40 °C to 70 °C

ENGINE SPECIFICATIONS

MAKE ................................................................................................................ Generac

MODEL..................................................................................................................V Type

CYLINDERS ................................................................................................................10

DISPLACEMENT ................................................................................................6.8 Liter

BORE ........................................................................................................................3.55

STROKE....................................................................................................................4.17

COMPRESSION RATIO ..............................................................................................9:1

INTAKE AIR SYSTEM........................................................................Naturally Aspirated

VALVE SEATS ..................................................................................................Hardened

LIFTER TYPE ....................................................................................................Hydraulic

GOVERNOR SPECIFICATIONS

TYPE ................................................................................................................Electronic

FREQUENCY REGULATION ..................................................................................± 1%

STEADY STATE REGULATION ............................................................................± 1/2%

ADJUSTMENTS

Speed......................................................................................................Yes

Droop ......................................................................................................Yes

ENGINE LUBRICATION SYSTEM

OIL PUMP ................................................................................................................Gear

OIL FILTER ..........................................................................................Full flow cartridge

CRANKCASE CAPACITY ..................................................................................5 Quarts

ENGINE COOLING SYSTEM

TYPE ....................................................................................................................Closed

WATER PUMP ................................................................................................Belt driven

FAN SPEED..............................................................................................................2095

FAN DIAMETER................................................................................................26 inches

FAN MODE..............................................................................................................Puller

FUEL SYSTEM

FUEL TYPE....................................................................................................Natural gas

CARBURETOR ..............................................................................................Down Draft

SECONDARY FUEL REGULATOR ..................................................................Standard

FUEL SHUT OFF SOLENOID ..........................................................................Standard

OPERATING FUEL PRESSURE..................................................................5” - 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp

STATIC BATTERY CHARGER........................................................................12V 2 Amp

RECOMMENDED BATTERY ......................................................................24F 625CCA

SYSTEM VOLTAGE ............................................................................................12 Volts

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

130 kW

OPERATING DATA

COMMERCIAL 130 kW
KW RATING 130
ENGINE SIZE 6.8 Liter V-10
GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 3.0 pf 277/480V, 3-phase, 3.0 pf KW 130 130 130 AMP 542 451 195 CB Size 600 500 225
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208 3-phase 480V 3-phase 270 320
ENGINE FUEL CONSUMPTION (Natural Gas) Exercise cycle ft3/hr. 25% of rated load ft3/hr. 50% of rated load ft3/hr. 75% of rated load ft3/hr. 100% of rated load ft3/hr. 301 482 927 1292 1786
ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/hr. Coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator ˚C (˚F) Max. ambient temperature ˚C (˚F) 6580 4.5 493,000 60 (150) 50 (140)
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 336
SOUND EMISSIONS IN DBA Exercising at 7 meters Full load at 7 meters 61 74
EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet ˚F 1000 925
ENGINE PARAMETERS Rated synchronous RPM 60 Hz HP at rated KW 60 Hz 3000 202
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 ˚C above - ˚C 1.65% for every 10 ˚F above - ˚F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 25 77 182 600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kW rating is based on LPG fuel and may derate with natural gas.

Installation layout diagram130 kW Generac Guardian generator

INTERCONNECTIONS

130 kW

NON-TERMINATED

INSTALLATION LAYOUT

UNIT WEIGHT 2873 LBS.

130 kW Commercial Generator from Generac Guardian  | Home

 